Product Overview
The GX/T2 is a 10/100/1000BASE-T UTP to 100BASE-FX or 1000BASE-X modular fiber media
converter that supports jumbo frames up to 10,240 bytes. The GX/T2 features Small Form Pluggable
(SFP) transceivers that support both 100BASE-FX and 1000BASE-X for interoperability with Fast
Ethernet and Gigabit fiber equipment.
Installation Procedure
1) Configure DIP-switches
2) Install Module in Chassis and Connect Cables
3) Verify Operation
1) CONFIGURE DIP-SWITCHES
DIP-SWITCH BANK 1
The location of the DIP-switches is shown in Figure
1. The functions of DIP-switch Bank 1 are outlined
in Figure 2.
SW1 and SW2: BACKPLANE ENABLE
When these DIP-switches are in the “DS” position
(factory default), the Backplane Port of the GX/T2
is isolated from the Ethernet Backplane on the
chassis. When these DIP-switches are in the
“EN” position, the Backplane Port is enabled.
This allows Ethernet Backplane connectivity to an
adjacent module via the chassis A/B Backplane
Link depending on the switch setting. Refer to the
chassis user manual for detailed information on
the Ethernet Backplane.
SW3 and SW4: Reserved
These DIP-switches are reserved and must be in the Down (default) position.
Switch
Legend
Function
DOWN (Default)
UP
SW1
A-DS/EN
Backplane A Enable/Disable
DS (Disable)
EN (Enable)
SW3
B-DS/EN
Backplane B Enable/Disable
DS (Disable)
EN (Enable)
SW3
-
Reserved
Off
On
SW4
-
Reserved
Off
On
Figure 2: DIP-switch BANK 1 Definitions
DIP-SWITCH BANK 2
The functions of DIP-switch Bank 2 are outlined in Figure 3.
SW1: Port 1 “Auto/100”
This DIP-switch configures the speed of the transceiver installed in Port 1. If the DIP-switch is
in the Down “Auto” (default) position, the port detects the data rate of the transceiver installed
and operates at 100M or 1G accordingly. If the DIP-switch is in the Up “100” position, the port is
expecting a 100M capable transceiver to be installed.
LED Function
“Legend”
Color
OFF State
ON/Blinking State
Power
“PWR”
Green
No power
Module has power
P1 Link Activity
1
“100”
Green/
Amber
Port not linked at 100M
Solid Green: Port linked at 100M
Blinking Green: Data activity
Blinking Amber: Port is operating at
100M and receiving FEFI
P1 Link Activity
“1000”
Green/
Amber
Port not linked at 1000M
Solid Green: Port linked at 1000M
Blinking Green: Data activity
Blinking Amber: Port is operating at
1000M and receiving a remote fault
P1 Link Activity
1
“100” and “1000”
Green
Port not linked at 10M
Solid Green: Port linked at 10M
Blinking Green: Data activity
P1 Duplex
“P1 FDX”
Green
Port is configured for half
duplex per DIP-switch or
resolved by auto-negotiation
Solid Green: Port is configured for
full duplex operation per DIP-switch or
resolved by auto-negotiation
P1 SFP DMMI Alarm
1
“P1 Stat”
Green/
Amber
Installed transceiver does not
support digital diagnostics or
no transceiver installed
Solid Green: Installed transceiver
supports digital diagnostics and no alarm
detected
Solid Amber: Installed transceiver has
detected an alarm
P2 Negotiation Mode
“P2 AN”
Green
Port is configured for Manual
operation
Solid Green: Port is configured for Auto-
negotiation
Blinking Green: Port is configured for
auto-negotiation but has not completed
the process with attached link partner
P2 Link Activity
“100”
Green/
Amber
Port not linked at 100M
Solid Green: Port linked at 100M
Blinking Green: Data activity
Blinking Amber: Port receiving a remote
fault at 100Mbps
P2 Link Activity
“1000”
Green/
Amber
Port not linked at 1000M
Solid Green: Port linked at 1000M
Blinking Green: Data activity
Blinking Amber: Port receiving a remote
fault at 1000Mbps
P2 Link Activity
“100” and “1000”
Green
Port not linked at 10M
Solid Green: Port linked at 10M
Blinking Green: Data activity
P2 Duplex
“P2 FDX”
Green
Port is configured for half
duplex per DIP-switch or
resolved by auto-negotiation
Solid Green: Port is configured for
full duplex operation per DIP-switch or
resolved by auto-negotiation
Figure 6: LED Indicators
1
LEDs are not installed on the fixed fiber models
LED Legend/State
Link Speed
“1000”
“100”
OFF
OFF
Port not linked
OFF
ON
Port linked at 100Mbps
ON
OFF
Port linked at 1000Mbps
ON
ON
Port linked at 10Mbps
Figure 7: Port Speed LED Indicators