L_io1000parcomguarding, Function library "lenzeio1000drv – Lenze Function library LenzeIO1000Drv User Manual
Page 52

Function library "LenzeIo1000Drv"
Function blocks
L_io1000ParComGuarding - Parameterising monitoring functions
52
L
DMS 1.0 EN - 07/2011 - TD05
4.12
L_io1000ParComGuarding - Parameterising monitoring functions
This FB serves to parameterise the monitoring functions provided by the I/O system.
This includes:
– NodeGuarding, heartbeat and Lenze-specific monitoring functions.
– Setting of the switching performance of the output channels in the event of an error
via the byErrorBehavior input.
A FALSE/TRUE edge at the bExecute input starts the parameter setting.
The dnState output shows the transmission status.
Call possible in:
;
Cyclic task
Interrupt task
;
Time-controlled task (INTERVAL)
Event-controlled task (EVENT)
L_io1000ParComGuarding
⎯ bExecute
bDone ⎯
⎯ dwHandle
dnState ⎯
⎯ byNodeAdr
DataTo_IOData15 ⎯
⎯ tGuardTime
DataTo_IOData610 ⎯
⎯ byLifeTimeFactor
⎯ tHeartbeatConsumerTime
⎯ byHeartbeatConsumerAdr
⎯ tHeartbeatProducerTime
⎯ byErrorBehavior
⎯ tTimeOutPDO1_DataToIO
⎯ tTimeOutPDO2_DataToIO
⎯ tTimeOutPDO3_DataToIO
⎯ tTimeOutPDO4_DataToIO
⎯ tTimeOutPDO5_DataToIO
⎯ tTimeOutPDO6_DataToIO
⎯ tTimeOutPDO7_DataToIO
⎯ tTimeOutPDO8_DataToIO
⎯ tTimeOutPDO9_DataToIO
⎯ tTimeOutPDO10_DataToIO
⎯ tTimeOutPDO1_DataFromIO
⎯ tTimeOutPDO2_DataFromIO
⎯ tTimeOutPDO3_DataFromIO
⎯ tTimeOutPDO4_DataFromIO
⎯ tTimeOutPDO5_DataFromIO
⎯ tTimeOutPDO6_DataFromIO
⎯ tTimeOutPDO7_DataFromIO
⎯ tTimeOutPDO8_DataFromIO
⎯ tTimeOutPDO9_DataFromIO
⎯ tTimeOutPDO10_DataFromIO