Function library "LenzeIo1000Drv"
Function blocks
L_io1000ParCounterEPMS600 - Parameterise counter
22
L
DMS 1.0 EN - 07/2011 - TD05
Outputs
dwLoadValue
DWORD
Load value
dwEndValue
DWORD
Final value
byHysteresis
BYTE
Hysteresis
byPulse
BYTE
Pulse duration
Identifier/data type
Value/meaning
bDone
BOOL
TRUE Parameter setting completed successfully
dnState
DINT
Status of parameter setting
• When the function has been executed successfully, the value "0" is output.
1 Parameter setting started
0 Parameter setting completed successfully
-1003 byNodeAdr input is not in valid range
-1004 Wrong value at byAnalogModuleNo input
-1007 Wrong value at byInputFrequencyTrackA input
-1008 Wrong value at byInputFrequencyTrackB input
-1009 Wrong value at byInputFrequencyLatch input
-1010 Wrong value at byInputFrequencyGate input
-1011 Wrong value at byInputFrequencyReset input
-1012 Wrong value at byAlarmFunction input
-1013 Wrong value at byCounterFunction input
-1014 Wrong value at bySignalSelection input
-1017 Wrong value at byCompareFunction input
-1019 Wrong value at byResetFunction input
-2000 Error while executing the internal block for writing CAN indices
-2002 Wrong value at the dwHandle input
-2003 Wrong value at the byNodeAdr input
-2006 Writing of a wrong CAN index
-2007 Timeout while writing a CAN index of the I/O system
-2100 Error while writing a parameter of the I/O system
-2101 Output buffer is full
Identifier/data type
Information/possible settings