Function library "LenzeIo1000Drv"

Function blocks

L_io1000ParCounterEPMS601 - Parameterise counter

Outputs

Identifier/data type

Value/meaning

bDone

BOOL

TRUE Parameter setting completed successfully

dnState

DINT

Status of parameter setting

• When the function has been executed successfully, the value "0" is output.

1 Parameter setting started
0 Parameter setting completed successfully

-1003 byNodeAdr input is not in valid range
-1004 Wrong value at byAnalogModuleNo input
-1007 Wrong value at byCnt0InputFrequencyTrackA input
-1008 Wrong value at byCnt0InputFrequencyTrackB input
-1009 Wrong value at byCnt0AlarmFunction input
-1010 Wrong value at byCnt0CounterFunction input
-1011 Wrong value at byCnt0SignalSelection input
-1013 Wrong value at byCnt0CompareFunction input
-1019 Wrong value at byCnt1InputFrequencyTrackA input
-1020 Wrong value at byCnt1InputFrequencyTrackB input
-1021 Wrong value at byCnt1AlarmFunction input
-1022 Wrong value at byCnt1CounterFunction input
-1023 Wrong value at byCnt1SignalSelection input
-1025 Wrong value at byCnt1CompareFunction input
-2000 Error while executing the internal block for writing CAN indices
-2002 Wrong value at the dwHandle input
-2003 Wrong value at the byNodeAdr input
-2006 Writing of a wrong CAN index
-2007 Timeout while writing a CAN index of the I/O system
-2100 Error while writing a parameter of the I/O system
-2101 Output buffer is full