beautypg.com

9 monitfollowerror, 9400 technology applications | electronic gearbox – Lenze E94AxHE Technology Application Electronic gearbox User Manual

Page 75

background image

EDS94TA10030xxxx EN 1.2 - 11/2009

L

75

9400 Technology applications | Electronic gearbox

Parameter setting & configuration

Parameterisable function blocks

5.16.9

MonitFollowError

C03983

DIS:bPosTeach

• Display of input signal bPosTeach.

0 FALSE
1 TRUE

C03984

DIS:bBusy

• Display of output signal bBusy.

0 Profile parameters are available.
1 Conversion active, no access to

profile parameters at the moment.

C03985

-2147483647

2147483647 State

• Display of the bit-coded output

signal dnState.

Parameter

Possible settings

Information

Is an instance of

Function

L_LdMonitFollowError

Following error monitoring ( 53)

Parameter

Possible settings

Information

C03960

-214748.3647

unit

214748.3647 Following error at the input

• Display of input signal

dnFollowErrorIn_p in real unit of

the machine.

C03961

Character string

Position unit

• Read only

C03963

Following error out of tolerance

• Read only

FALSE Following error smaller than set

switching threshold

TRUE Following error larger than set

switching threshold

C03964

Following error monitoring activated

• Read only

FALSE Deactivated

TRUE Activated