1 master value source: virtual master, 9400 technology applications | electronic gearbox – Lenze E94AxHE Technology Application Electronic gearbox User Manual
Page 42
9400 Technology applications | Electronic gearbox
Parameter setting & configuration
Selection of master value source and output
42
L
EDS94TA10030xxxx EN 1.2 - 11/2009
5.3.1
Master value source: Virtual master
If the "Virtual master" is selected as master value source, the master value is created in the
TA and transmitted via a bus system or the digital frequency output to the other slave
drives.
Parameter setting: Tab Application parameters dialog level Overview Virtual
master
Configuration: Tab FB editor FB
Parameter
Lenze setting
Value Unit
C03565
Operating mode
Continuous operation
C03568/1
Master speed 1
500.0000 unit/t
C03568/2
Master speed 2
0.1000 unit/t
C03569/1
Speed inching right
50.0000 unit/t
C03569/2
Speed inching left
25.0000 unit/t
C03570/1
Inching ramp
0.010 s
C03570/2
Continuous operation ramp
1.000 s
C03570/3
Stop ramp
1.000 s
Control/setpoint inputs of the function
Signal configuration
Lenze setting
Control/setpoint input
(Multiplexer parameters)
FALSE VMas master shaft STOP1
C03058/1
C03016 Activate master function
C03058/3
C03017 VMas inching positive
C03058/4
C03018 VMas inching negative
C03058/5
FALSE VMas start continuous operation
C03058/7
FALSE VMas 2. master speed
C03058/8
0 VMaster handwheel
C03056