beautypg.com

1 master value source: virtual master, 9400 technology applications | electronic gearbox – Lenze E94AxHE Technology Application Electronic gearbox User Manual

Page 42

background image

9400 Technology applications | Electronic gearbox

Parameter setting & configuration

Selection of master value source and output

42

L

EDS94TA10030xxxx EN 1.2 - 11/2009

5.3.1

Master value source: Virtual master

If the "Virtual master" is selected as master value source, the master value is created in the

TA and transmitted via a bus system or the digital frequency output to the other slave

drives.

Parameter setting: Tab Application parameters  dialog level Overview Virtual

master

Configuration: Tab FB editor  FB

VirtualMaster

Parameter

Lenze setting

Value Unit

C03565

Operating mode

Continuous operation

C03568/1

Master speed 1

500.0000 unit/t

C03568/2

Master speed 2

0.1000 unit/t

C03569/1

Speed inching right

50.0000 unit/t

C03569/2

Speed inching left

25.0000 unit/t

C03570/1

Inching ramp

0.010 s

C03570/2

Continuous operation ramp

1.000 s

C03570/3

Stop ramp

1.000 s

Control/setpoint inputs of the function

Signal configuration

Lenze setting

Control/setpoint input

(Multiplexer parameters)

FALSE  VMas master shaft STOP1

C03058/1

C03016  Activate master function

C03058/3

C03017  VMas inching positive

C03058/4

C03018  VMas inching negative

C03058/5

FALSE  VMas start continuous operation

C03058/7

FALSE  VMas 2. master speed

C03058/8

0  VMaster handwheel

C03056