14 application error messages, 9400 technology applications | electronic gearbox – Lenze E94AxHE Technology Application Electronic gearbox User Manual
Page 63
EDS94TA10030xxxx EN 1.2 - 11/2009
L
63
9400 Technology applications | Electronic gearbox
Parameter setting & configuration
Application error messages
5.14
Application error messages
For the output of application-specific error messages an FB instance ApplicationError of the
function block L_DevApplErr is available in the network.
Via the 8 boolean inputs up to 8 different application error messages with
parameterisable module ID, error ID and error response can be activated by the
application.
The first four inputs can be connected to the multiplexer parameters with the desired
tripping signals. The next four inputs are firmly connected to the tripping signals of the
application.
Parameter setting: Tab All parameters
Error message
Error ID
Error response
1
Free (configurable via C03060/1)
8001
No response
2
Free (configurable via C03060/2)
8002
Error
3
Free (configurable via C03060/3)
8003
Error
4
Free (configurable via C03060/4)
8004
Error
5
Following error
8005
Warning
6
Drive cannot follow
8006
Warning
7
Drive system interrupted
8007
Quick stop by trouble
8
External fault in drive system
8008
Quick stop by trouble
Parameter
Lenze setting
C05900
Module ID
999
C05901/1...8
Error ID 1 ... 8
See table above
C05902/1...8
Error response 1 ... 8
See table above
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
FALSE Application fault 1
C03060/1
FALSE Application fault 2
C03060/2
FALSE Application fault 3
C03060/3
FALSE Application fault 4
C03060/4