4 electricalshaftdata, 9400 technology applications | electronic gearbox – Lenze E94AxHE Technology Application Electronic gearbox User Manual
Page 71
EDS94TA10030xxxx EN 1.2 - 11/2009
L
71
9400 Technology applications | Electronic gearbox
Parameter setting & configuration
Parameterisable function blocks
5.16.4
ElectricalShaftData
Is an instance of
Function
L_SdSetAxisData
Mapping of the machine parameters of the higher-level drive (master shaft).
Master axis (master shaft) ( 38)
Parameter
Possible settings
Information
C03930
1
2147483647 Gearbox ratio - numerator
• Initialisation: 1
C03931
1
2147483647 Gearbox ratio - denominator
• Initialisation: 1
C03932
0.0001
Unit/incr.
214748.3647 Feed constant
• Initialisation: 360 units/incr.
C03933
Path unit
0 User-defined
Selection in C03934
1 Inc
2 μm
3 mm
4 m
5 inch
6 yard
7 °
Lenze setting
C03934
Character string, max. 8 characters
User-defined path unit
C03935
At present, the unit of the time base is
permanently set to "s" and cannot be
changed!
Time unit
C03938
0.0000
unit
214748.3647 Cycle
• Initialisation: 360 units
C03939
10
Bit
24 Resolution of encoder revolution
• Initialisation: 16 bits
C03941
-214748.3647
unit/t
214748.3647 Reference speed
• Initialisation:
214748.3647 units/t
C03942
Traversing range
0 Unlimited
1 Limited
2 Modulo
Lenze setting
C03948
-2147483.647
2147483.647 Resulting gearbox factor
• Read only
C03949
-214748.3647
Incr.
214748.3647 Resolution of application unit
• Read only