Short setup
Step 2: Parameterising the application
28
L
EDS94TA10030xxxx EN 1.2 - 11/2009
Machine parameters
1. Set gearbox ratio for the motor in the form of a quotient (numerator and
denominator): i
2
= 12.612 = 12612/1000
– Numerator (C02520) = 12612
– Denominator (C02521) = 1000
2. Set the same gearbox ratio for the encoder on the load side:
– Numerator (C02522) = 12612
– Denominator (C02523) = 1000
3. Set feed constant (C02524).
– The feed constant corresponds to the motion of the machine at one revolution of the
gearbox output shaft.
– For the conveyor drive: Vk = d
2
* π = 628,3185 mm
4. Set the selection "mm" as unit (C02525).
– This parameter is used to define the real unit of the machine for the selection of
physical values (e. g. speeds, accelerations and decelerations).
5. Click Back to go back to the Electronic gearbox dialog level.
6. In the Electronic gearbox dialog level, click Master value processing to change to the
Master value processing dialog level.
Go to dialog:
Overview