Short setup

Step 2: Parameterising the application

28

L

EDS94TA10030xxxx EN 1.2 - 11/2009

Machine parameters

1. Set gearbox ratio for the motor in the form of a quotient (numerator and

denominator): i

2

= 12.612 = 12612/1000

– Numerator (C02520) = 12612
– Denominator (C02521) = 1000

2. Set the same gearbox ratio for the encoder on the load side:

– Numerator (C02522) = 12612
– Denominator (C02523) = 1000

3. Set feed constant (C02524).

– The feed constant corresponds to the motion of the machine at one revolution of the

gearbox output shaft.

– For the conveyor drive: Vk = d

2

* π = 628,3185 mm

4. Set the selection "mm" as unit (C02525).

– This parameter is used to define the real unit of the machine for the selection of

physical values (e. g. speeds, accelerations and decelerations).

5. Click Back to go back to the Electronic gearbox dialog level.
6. In the Electronic gearbox dialog level, click Master value processing to change to the

Master value processing dialog level.

Go to dialog:

Overview

Electronic gearbox

Machine parameters