beautypg.com

5 parameter setting & configuration, 1 basic signal flow, Parameter setting & configuration – Lenze E94AxHE Technology Application Electronic gearbox User Manual

Page 36: 9400 technology applications | electronic gearbox, 5parameter setting & configuration

background image

9400 Technology applications | Electronic gearbox

Parameter setting & configuration

Basic signal flow

36

L

EDS94TA10030xxxx EN 1.2 - 11/2009

5

Parameter setting & configuration

5.1

Basic signal flow

[5-1]

Signal flow of the TA "Electronic gearbox" (schematic diagram)

Functions in the operating mode "Electronic gearbox"

Master value processing with stretch factor

Virtual clutch

Master value trimming

Setpoint conditioning

Basic drive functions

Homing

Manual jog (inching)

Position override function

Quick stop

Limiter (optional)

Brake control (optional)

v

t

Dv

M

v

Slave

LS_ManualJog

n

t

и

з

n

t

LS_Positioner

0

-100

100 200

LS_Homing

4

5

6

LS_Brake

n

t

LS_Limiter

n

t

LS_Quickstop

STOP

7

8

9

Real master/

Virtual master

0

1

2

3