9400 Technology applications | Electronic gearbox
Parameter setting & configuration
Quick stop
54
L
EDS94TA10030xxxx EN 1.2 - 11/2009
5.9
Quick stop
[5-12] Basic function "Quick stop" (schematic diagram)
The quick stop function can be activated as follows in the Lenze setting:
– By setting the digital input DI1 to LOW level.
– By a master control via the port LPortControl1:
By setting bit 2 of the bit-coded control word 1.
Parameter setting: Tab Application parameters dialog level Overview All basic
functions Quick stop
The basic function "Quick stop" brakes the
drive to standstill within the deceleration
time set for the quick stop function after a
corresponding request independent of the
setpoint selection.
If the quick stop function is deactivated,
the drive is led to the selected setpoint
again via the set acceleration time.
v
t
t
M
Slave
n
t
LS_Limiter
n
t
LS_Quickstop
STOP
Parameter
Lenze setting
Value Unit
C00105
Quick stop deceleration time
0.000 s
C00106
Quick stop S-ramp time
0.00 %
C00107
Reference for quick stop
deceleration time
Motor reference speed (C00011)
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
DIGIN 1 Activate quick stop 1
C03135/1
Control word 1
bit 02
Activate quick stop 2
C03135/2
FALSE Activate quick stop 3
C03135/3