6 "manual jog" mode, 9400 technology applications | electronic gearbox – Lenze E94AxHE Technology Application Electronic gearbox User Manual
Page 50
9400 Technology applications | Electronic gearbox
Parameter setting & configuration
"Manual jog" mode
50
L
EDS94TA10030xxxx EN 1.2 - 11/2009
5.6
"Manual jog" mode
In the "Manual jog" mode (C03006 = "4") the drive is decoupled from the electrical shaft
and the basic function "Manual jog" is enabled:
[5-10] "Manual jog" mode (schematic diagram)
Parameter setting: Tab Application parameters dialog level Overview Manual jog
v
t
LS_ManualJog
n
t
и
з
n
t
LS_Positioner
0
-100
100 200
LS_Homing
C03006 = 4
t
M
Slave
Parameter
Lenze setting
Value Unit
C02620
Manual jog: Speed 1
360.0000 unit/s
C02621
Manual jog: Speed 2
720.0000 unit/s
C02622
Manual jog: Acceleration
360.0000 unit/s
2
C02623
Manual jog: Deceleration
1440.0000 unit/s
2
C02624
Manual jog: S-ramp time
0.100 s
C03007
Positive manual jog
Inactive
C03008
Negative manual jog
Inactive
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
C03007 Activate positive manual jog
C03155/2
C03008 Activate negative manual jog
C03155/3
FALSE Activate 2. speed
C03155/4
FALSE Retract limit switch
C03155/5