7 connection, terminal wiring, 1 power stack, 1 3ac supply – Lenze EDB9300UES User Manual
Page 50: Connection, terminal wiring, Power, Stack, Supply

Technical Data
BA8230
45
2.7 Connection, terminal wiring
2.7.1 Power stack
The power stack consists of a B6 diode input bridge, charging circuit, link and inverter.
The AC bridge connections U1, V1, W1 are connected to the 3-phase AC supply
network L1, L2, and L3.
2.7.1.1 3AC supply
Connections at top
Function
PE
Earth terminal
L1
L2
Mains supply 3AC 400 ... 460 V
L3
-
Not used
RB1
Braking resistor
+UG
(+UG = link plus)
Connections at foot
Function
PE
Earth terminal
U1
V1
Motor connection
W1
+UG
Link plus
-UG
Link minus
PE
Earth terminal
Fig. 18 shows the 8230 frequency inverter power connections for a 3AC supply. The
8230 frequency inverter supply components marked * are not essential.
Note:
In exceptional cases it can be necessary to reverse the order of components 1), see
Fig. 18. This is the case, for example, if additional auxiliary supplies such as external
motor fans are to be operated at the feed point or function earthing is not consistent.
}
}
}
Show/Hide Bookmarks