Technical Data
BA8230
11
•
Frequency accuracy for
frequency control
<0.01 %
•
Temperature response
of analog demand
<0.01 %/°C
•
Speed encoder
incremental encoder
see encoder interface option
•
Noise
A-weighted sound pressure level
frame size 8
<70 dB(A)
frame size 8A
<73 dB(A)
frame size 9
<72 dB(A)
frame size 9A
<74 dB(A)
•
Overtemperature shutdown
frame size 8 at
>95 °C
frame size 8A at
>105 °C
frame size 9 at
>105 °C
frame size 9A at
>105 °C
•
Ambient temperature
Operation
0 ... +55 °C
1)
Storage
-25 °C ... +65 °C
•
Cooling
corced air cooling
see section 2.2.3 for cooling air volumes
•
Coolant temperature
0 ... 40 °C at rated current, overload factor 1.2
for 60 s every 10 minutes
up to max. 55 °C with power reduction 2 % per 1 °K
0 ... 50 °C at rated current, overload factor 1.5
for 60 s every 10 minutes
up to max. 55 °C with power reduction 2 % per 1 °K
•
Installation altitude
≤
1000 m above MSL, up to max. 2200 m with
power reduction 1.2 % per 100 m
•
Storage time
Without reforming the capacitors: 2 years, 5 months
of which at temperatures over 40°C
•
Protection classes
Build-in units
IP20
Cubicle-mounted units
IP21 Standard
IP31, IP43, IP54 Option
•
Environment class
DIN EN 60721 Part 3-3
3K3 / 3M2 / 3C2
2)
/ 2K2
- Max. relative humidity
85 % at 28 °C, condensation not permitted
- Insulation
Contamination Class II to DIN VDE 0110
•
Permitted switching
Precharging circuit duty cycle = 2 %/180 s,
frequency
max. 20 per hour
•
Power loss of control
ca. 130 W
electronics
with control board, no additional options