5 parameters for digital i/o's, Parameters for digital i/o’s – Lenze EDB9300UES User Manual
Page 124

Operation and Software
BA8230
119
4.4.5 Parameters for digital I/O’s
D-Input 1 terminal 14
This parameter determines the function of the digital control input at terminal 14. The
function is active at logic “High”.
Select list:
- Motor potentiometer higher
- Select fixed speed1
As supplied:
Motor potentiometer higher
If the parameter is set to "Select fixed speed 1", one of the fixed speeds stated in
02 Application parameters according to the following table is activated in conjunction
with the function “Select fixed speed 2”:
Select fixed speed 1
Select fixed speed 2
Activated fixed speed
0
0
"Fixed speed 1"
1
0
"Fixed speed 2"
0
1
"Fixed speed 3"
1
1
"Fixed speed 4"
"Fixed speed 1" to "Fixed speed 4" are specified in 02 = APPLICATION
PARAMETERS.
IMPORTANT!
If the function of D-Input terminal :14 is not set to "Select fixed speed 1", the selection
matrix for Select fixed speed 1 is 0.
The activated fixed speeds are only effective if the parameter for the MANUAL
demand or AUTO demand in Menu 03 Configuration is set to fixed speed.
D-Input 2 terminal 15
This parameter determines the function of the digital control input at terminal :15. The
function is active at logic “High”.
Select list:
- Motor potentiometer lower
- Select fixed speed 2
As supplied:
Motor potentiometer lower
If the parameter is set to "Select fixed speed 2", one of the fixed speeds given in
02 Application parameters according to the following table is activated in conjunction
with the function “Select fixed speed 1”: