Commissioning, With hand terminal – Lenze EDK71MMXXX−010 User Manual
Page 104
7
Commissioning
With hand terminal
EDK71MMXXX−010 DE/EN/FR 5.0
L
104
)
Note!
l
Adhere to the switch−on sequence.
l
In case of faults during commissioning, the chapter on "Troubleshooting"
provides support (
^ 128).
Switch−on sequence
Comment
1.
Connect hand terminal to AIF
interface
2.
Ensure that the starttec is inhibited
after mains switch−on
Terminal X3/28 = LOW
3.
Switch on mains
4.
Switch on 24−VDC supply
5.
After approx. 2 s, the hand terminal
is in Disp" mode and displays the
apparent motor current (C0054)
start015
00
0
0054
000
1
c
d
j g f k i h PS
A
The
USEr
menu is active
6.
Change to the
f
mode to set the
parameters of the drive
start016
00
0
0054
000
1
c
d
j
g f k i h PS
A
w x
z
y
0054
flashes on the display
7.
Scroll down on C0006
start037
00
0
0006
000
1
c
d
j
g f k i h PS
A
w x
z
y
0006
flashes on the display
8.
To change the setting of the
potentiometers or the stepping
switch using the hand terminal, set
C0006 accordingly
Lenze setting: −0−
C0006
C0012
C0016
C0120
l
PU: Potentiometer "U
o
"
for starting voltage
l
PT: Potentiometer "T" for
acceleration time
l
S: Stepping switch for
rated motor current
l
H: Hand terminal
Important!
When switching to hand
terminal, the values set with
PU, PT and S are
transferred.
0
PT
PU
S
1
PT
PU
H
2
PT
H
S
3
PT
H
H
4
H
PU
S
5
H
PU
H
6
H
H
S
7
H
H
H