With hand terminal, Commissioning – Lenze EDK71MMXXX−010 User Manual
Page 100

7
Commissioning
With hand terminal
EDK71MMXXX−010 DE/EN/FR 5.0
L
100
The hand terminal E82ZBB and the required connecting cable are available as accessories. The folder
accompanying the hand terminal contains a complete description.
0
Function keys
1
Status displays
2
Bar graph display
3
Function bar 1
4
Function bar 2
5
Parameter set
Change is
possible if
display
flashes
6
Code number
7
Subcode number
8
Parameter value with unit
Menu structure
All parameters that can be used to parameterise or monitor the drive are stored in codes in the menus
user and all. The codes are numbered 6 and identified with a "C" in the text. In some codes, the
parameters are stored in numbered subcodes"
7 to maintain a clear overview of the parameter
setting (example: C0517
user) menu.
l
The
user
l
menu
– is active after every mains switching if the hand terminal is connected or if you connect the
hand terminal to the AIF interface during operation.
– is factory−equipped with all codes to commission a standard application.
– can be individually compiled in C0517.
l
The
all
l
menu
– contains all codes.
– lists codes sorted in numerical ascending order.
l
The following pages describe how you can toggle between
userand all and change the
parameters in the codes.