17 homing method 19: homing without an index pulse, Programming – Lenze PM94P01C User Manual
Page 77

PM94P01C
75
Programming
2.15.9.17
Homing Method 19: Homing without an Index Pulse
Using this method the initial direction of movement is positive (if the homing switch is inactive). The home position is the
leading edge of the homing switch.
Axis will accelerate to
fast homing velocity in the positive direction and continue until the homing switch is activated
(rising edge) shown at position A. Axis then decelerates to zero velocity.
If the homing switch is already active when the homing routine commences then this initial move is not executed.
Axis will then accelerate to
fast homing velocity in the negative direction. Motion will continue until the falling edge of
the homing switch is detected (position B), where the axis will decelerate to 0 velocity.
Axis will then accelerate to
slow homing velocity in the positive direction. Motion will continue until the rising edge of the
homing switch is detected (position C), where the axis will decelerate to 0 velocity.
Axis will then accelerate to
slow homing velocity in the negative direction. Motion will continue until the falling edge of
the homing switch is detected (position 19). This is the home position (excluding offset).
A
B
19
C
Homing Switch
(Var_Home_Switch_Input)
Figure 41: Homing Method 19