When retrieving data with MEMGET statements memory locations will be sequentially copied to variables starting from
the one with smallest index in the list to the last with biggest index. Consider the list for the MEMGET statement:
[V2,V3,V5-V7]
RAM file memory
Data1
Data2
Data3
Data4
Data5
Data6
...
... index increase
Here is how the data will be assigned to variables:
V2 <- Data1
V3 <- Data2
V5 <- Data3
V6 <- Data4
V7 <- Data5
2.8
System Variables and Flags Summary
2.8.1 System Variables
Section 3.2 provides a complete list of the system variables. Every aspect of the PositionServo can be controlled by
the manipulation of the values stored in the System Variables. All System Variables start with a “VAR_” followed by the
variable name. Alternatively, System Variables can be addressed as an @NUMBER where the number is the variable
Index. The most frequently used variables also have alternate names listed in Table 12.
Table 12: System Variables
Index
Variable
Access Variable Description
Units
181
ACCEL
R/W
Acceleration for motion commands
User Units/Sec
2
71
AIN1
R
Analog input. Scaled in volts. Range from -10 to +10 volts
V(olt)
72
AIN2
R
Analog input 2. Scaled in Volts. Range from -10 to +10 volts
V(olt)
88
AOUT
R/W
Analog output. Value in Volts. Valid range from -10 to +10 (V)
(2)
V(olt)
215
APOS
R/W
Actual motor position
User Units
190
APOS_PLS
R/W
Actual Motor Position
Encoder Counts
182
DECEL
R/W
Deceleration for motion commands
User Units/Sec
2
83
DEXSTATUS
R
Drive Extended Status Word
-
54
DSTATUS
R
Status flags register
-
DFAULTS
R
Fault code register
-
245
HOME
W
Start Homing (pre-defined homing)
-
INDEX
R
Lower 8 bits are used. See ASSIGN statement for details.
-
184
INPOSLIM
R/W
Maximum deviation of position for INPOSITION Flag to remain set
User Units
65
INPUTS
R
Digital Inputs states. The first 12 bits correspond to the 12 drive inputs
-
139
IREF
W
Internal Reference: Velocity / Torque
RPS/A
187
MECOUNTER
R
Master Encoder Counts (Master Encoder Input)
Encoder Counts
180
MAXV
R/W
Maximum velocity for motion commands
User Units/Sec
140-
171
NV0 - NV31
R/W
User Network Variables
-
66
OUTPUTS
R/W
Digital outputs. Bits #0 to #4 represent outputs 1 through 5
-
216
PERROR
R
Position Error
Feedback Pls
191
PERROR_PLS
R
Position Error
User Units
48
PGAIN_D
R/W
Position loop D-gain
-
47
PGAIN_I
R/W
Position loop I-gain
-
49
PGAIN_ILIM
R/W
Position loop I gain limit
-
46
PGAIN_P
R/W
Position loop P-gain
-