6 appendix, 1 signal functions for analog inputs epm-t310, Signal functions for analog inputs epm−t310 – Lenze DDS Function library IOSystem User Manual
Page 71: Function library lenzeiosystem.lib, 6appendix, Appendix, 1 signal functions for analog inputs epm−t310
Function library LenzeIOSystem.lib
Appendix
6.1
Signal functions for analog inputs EPM−T310
6−1
L
LenzeIOSystem.lib EN 1.7
6
Appendix
6.1
Signal functions for analog inputs EPM−T310
Parameter
bytes 2/3/4/5
Signal function
Signal range
Format
Tolerance
1)
00
h
Parameter data in module not overwritten
01
h
Temperature measuring
with two−wire connection
(complement on two)
with PT100
−200.0
{0.1 °C}
+850.0
A
±1 °C
2)
02
h
with PT1000 −200.0
{0.1 °C}
+500.0
±1 °C
2)
03
h
with NI100
−50.0
{0.1 °C}
+250.0
±1 °C
2)
04
h
with NI1000
−50.0
{0.1 °C}
+250.0
±1 °C
2)
05
h
Resistance measuring with
two−wire connection
at 60
W
0
0
{0.01
W}
{1 dec}
+60.00
32767
A
±0.2 % of limit value
2)
05
h
at 600
W
0
0
{0.01
W}
{1 dec}
+600.00
32767
±0.2 % of limit value
2)
07
h
at 3000
W
0
0
{0.01
W}
{1 dec}
+3000.00
32767
±0.2 % of limit value
2)
08
h
at 6000
W
0
0
{0.01
W}
{1 dec}
+6000.00
32767
±0.2 % of limit value
2)
09
h
Temperature measuring
with four−wire connection
(complement on two)
with PT100
−200.0
{0.1 °C}
+850.0
A
±0.5 °C
0A
h
with PT1000 −200.0
{0.1 °C}
+500.0
±0.5 °C
0B
h
with NI100
−50.0
{0.1 °C}
+250.0
±0.5 °C
0C
h
with NI1000
−50.0
{0.1 °C}
+250.0
±0.5 °C
0D
h
Resistance measuring with
two−wire connection
at 60
W
0
{0.01
W}
+60.00
A
±0.1 % of limit value
0E
h
at 600
W
0
{0.01
W}
+600.00
±0.05 % of limit value
0F
h
at 3000
W
0
{0.01
W}
+3000.00
±0.05 % of limit value
10
h
Temperature measuring
with thermocouple and
external compensation
3)
(complement on two)
with type J
−210.0
{0.1 °C}
+850.0
A
±1 °C
11
h
with type K
−270.0
{0.1 °C}
+1200.0
±1.5 °C
12
h
with type N
−200.0
{0.1 °C}
+1300.0
±1.5 °C
13
h
with type R
−50.0
{0.1 °C}
+1760.0
±4 °C
14
h
with type T
−270.0
{0.1 °C}
+400.0
±1.5 °C
15
h
with type S
−50.0
{0.1 °C}
+1760.0
±5 °C
18
h
Temperature measuring
with thermocouple and
internal compensation
4)
(complement on two)
with type J
−210.0
{0.1 °C}
+850.0
A
±1.5 °C
19
h
with type K
−270.0
{0.1 °C}
+1200.0
±2 °C
1A
h
with type N
−200.0
{0.1 °C}
+1300.0
±2 °C
1B
h
with type R
−50.0
{0.1 °C}
+1760.0
±5 °C
1C
h
with type T
−270.0
{0.1 °C}
+400.0
±2 °C
1D
h
with type S
−50.0
{0.1 °C}
+1760.0
±5 °C
27
h
Voltage measuring
(complement on two)
0 ... 50 mV
0
0
{0.01 mV}
{1 dec}
+50.00
27648
A
±0.1 % of limit value
Lower range limit:
–
Upper range limit:
+59.25 mV
32767 dec
29
h
Voltage measuring
(complement on two)
±4 V
−4.00
−27648
{0.01 V}
{1 dec}
+4.00 V
27648 dec
A
±0.05 % of limit value
Lower range limit:
−4.74 V
−32767 dec
Upper range limit:
+4.74 V
32767 dec
2A
h
Voltage measuring
(complement on two)
±400 mV
−400
−27648
{1 mV}
{1 dec}
+400
27648
A
±0.1 % of limit value
Lower range limit:
−474 mV
−32767 dec
Upper range limit:
+474 mV
32767 dec
3B
h
Voltage measuring
(complement on two)
±10 V
−10.00
−16384
{0.01 V}
{1 dec}
+10.00
16384
B
±0.2 % of limit value