Function library lenzeiosystem.lib, Function blocks – Lenze DDS Function library IOSystem User Manual
Page 24
4.2
L_IOParAlnModule − Parameterisation function
Function library LenzeIOSystem.lib
Function blocks
4−6
L
LenzeIOSystem.lib EN 1.7
Outputs
ð
(Variable type: VAR_OUTPUT)
Identifiers
Data type
Value/meaning
nState
Integer
States
If a transmission error occurs during the parameterisation process or the input data
are incorrect, the parameterisation process is aborted and an error number is
indicated at output nState.
Errors are reset via an edge reversal at input bExecute or on
program restart.
0 Transmit request is executed.
The module is parameterised.
1 Transmit request dropped
Processing is running
2001 Error occurred during bus transfer
2002 Transmit request timed out
2004 Access denied
Incorrect target system: index does not exist
2005 Access denied
Incorrect target system: subindex does not exist
2013 Access denied
Incorrect target system: invalid value range
2111 Access denied
Incorrect target system: more than 4 decimal positions
specified or no fixed point format index
2117 Communication channel does not exist
byCom−Channelsetting
−10xx Incorrect value at function block input.
XX := number of the faulty input (counting direction
downwards), parameterisation impossible.
Remedy: change input value, restart data transmission