Configuration of the digital frequency input signal
·
The type of the digital frequency input signal is configured under C0427:
Code
LCD
Possible settings
Info
Lenze
Selection
C0427 DFIN function
0
Type of the digital frequency signal
0
2 phases
1
A = Speed / B = Direction
2
A or B = Speed or direction
C0427 = 0 (2 phases)
B
B
A
A
Z
Z
Track
CW rotation
CCW rotation
A
leads track B by 90º
(DFIN_nIn_v = positive value)
lags behind track B by 90º
(DFIN_nIn_v = negative value)
B
−
−
Signal sequence with phase shift (CW rotation)
C0427 = 1 (A = Speed / B = Direction)
B
B
A
A
Z
Z
Track
CW rotation
CCW rotation
A
transmits the speed
transmits the speed
B
= FALSE
(DFIN_nIn_v = positive value)
= TRUE
(DFIN_nIn_v = negative value)
Control of the direction of rotation via track B
C0427 = 2 (A or B = speed or direction)
B
B
A
A
Z
Z
Track
CW rotation
CCW rotation
A
transmits the speed and the direction
of rotation
(DFIN_nIn_v = positive value)
= FALSE
B
= FALSE
transmits the speed and the direction
of rotation
(DFIN_nIn_v = negative value)
Control of the speed and the direction of rotation