9300 Servo PLC EN 5.0
Code
Info
Possible settings
LCD
Code
Info
Selection
Lenze
LCD
C0517 User menu
User menu with up to 32 entries
·
The numbers of desired codes are entered under the
subcodes.
·
The data is input in xxx.yy format
– xxx: Code number
– yy: Subcode for code
·
There is no check whether the entered code exists.
0.00
{0.01}
7999.00
1
51.00
C0051/0
MCTRL−NACT
2
54.00
C0054/0
Imot
3
56.00
C0056/0
MCTRL−MSET2
4
0.00
Not assigned
5
0.00
Not assigned
6
183.00
C0183/0
Diagnostics
7
168.01
C0168/1
Fail number
8
86.00
C0086/0
Mot type
9
22.00
C0022/0
Imax current
10
0.00
Not assigned
11
11.00
C0011/0
Nmax
12
0.00
Not assigned
13
0.00
Not assigned
14
105.00
C0105/0
QSP Tif
15
0.00
Not assigned
16
70.00
C0070/0
Vp speed CTRL
17
71.00
C0071/0
Tn speed CTRL
18
1500.00
C1500/0
19
2100.00
C2100/0
Time slice
20
2102.00
C2102/0
Task switch
21
2104.00
C2104/0
PLC Autorun
22
0.00
23
2108.00
C2108/0
PLC run/stop
24
0.00
Not assigned
...
...
...
30
0.00
Not assigned
31
94.00
C0094/0
Password
32
3.00
C0003/0
Par save
C0540 Function
2
Digital frequency output DFOUT_IO_DigitalFrequency:
Function
·
X9 is inhibited if 0, 1, or 2 have been selected.
·
DFOUT_nIn_v = 0 if 4 or 5 have been selected.
·
The input signals are buffered electrically.
0
DFOUT_nOut_v as %
1
DFOUT_nOut_v as rpm
2
Incremental encoder simulation + zero pulse
4
X9 is output on X10
5
X8 is output on X10
C0545 PH offset
0
Digital frequency output DFOUT_IO_DigitalFrequency:
Phase offset of the zero pulse for incremental encoder
simulation (1 rev. = 65535 inc.)
0
{1 inc}
65535
C0547 DFOUT_nOut_v
g
Digital frequency output DFOUT_IO_DigitalFrequency:
DFOUT_nOut_v as analog value (if C0540 = 0)
−199.99
{0.01 %}
199.99