9300 servo plc, Appendix, 6 code table – Lenze Drive PLC Developer Studio 9300 Servo PLC (V8.x) User Manual
Page 145

9300 Servo PLC
Appendix
3.6
Code table
3−43
L
9300 Servo PLC EN 5.0
Code
Info
Possible settings
LCD
Code
Info
Selection
Lenze
LCD
C0586 MONIT SD2
0
Monitoring configuration: Resolver error
0
TRIP
2
Warning
3
Off
C0587 MONIT SD3
3
Monitoring configuration: Encoder error at X9/pin 8
0
TRIP
2
Warning
3
Off
C0588 MONIT H10/H11
3
Monitoring configuration: Temperature sensors
(Heatsink temperature/temperature inside the controller)
0
TRIP
2
Warning
3
Off
C0591 MONIT CE1
3
System bus: Monitoring configuration
CAN1_IN communication error (CE1)
0
TRIP
2
Warning
3
Off
C0592 MONIT CE2
3
System bus: Monitoring configuration
CAN2_IN communication error (CE2)
0
TRIP
2
Warning
3
Off
C0593 MONIT CE3
3
System bus: Monitoring configuration
CAN3_IN communication error (CE3)
0
TRIP
2
Warning
3
Off
C0594 MONIT SD6
à
Monitoring configuration: Motor temperature sensor error
(X7 or X8)
à
Dependent on C0086
0
TRIP
2
Warning
3
Off
C0595 MONIT CE4
3
System bus: Monitoring configuration
"BusOffState" (CE4)
0
TRIP
2
Warning
3
Off
C0596 NMAX limit
5500
Monitoring configuration: Max. speed of the machine
0
{1 rpm}
16000
C0597 MONIT LP1
3
Configuration of motor phase monitoring (LP1)
0
TRIP
2
Warning
3
Off
·
Setting of the monitoring limit via C0599
C0598 MONIT SD5
3
Monitoring configuration: Master current at X6/1, 2
(Master current < 2 mA)
0
TRIP
2
Warning
3
Off
C0599 Limit LP1
5
LP1 fault monitoring limit
0.01
{0.01 %}
10.00
C0603 MONIT CE5
3
System bus: Monitoring configuration
Time−out with remote parameter setting activated (C0370)
0
TRIP
2
Warning
3
Off