9300 servo plc, Appendix – Lenze Drive PLC Developer Studio 9300 Servo PLC (V8.x) User Manual
Page 132

3.6
Code table
9300 Servo PLC
Appendix
3−30
L
9300 Servo PLC EN 5.0
Code
Info
Possible settings
LCD
Code
Info
Selection
Lenze
LCD
C0128 TAU motor
5,0
Thermal time constant of the motor
The time constant is required for calculating the
I
2
× t−disconnection.
0.1
{0.1 min}
50.0
C0135 System Var
0
Internal code
·
Control word for networking via automation interface
(AIF)
·
FCODE_bC135Bit0_b ... FCODE_bC135Bit15_b
0
{1}
65535
Decimal value is bit−coded:
Bit 00
freely configurable 0
Bit 01
freely configurable 1
Bit 02
freely configurable 2
Bit 03
quick stop (QSP)
Bit 04
freely configurable 4
Bit 05
freely configurable 5
Bit 06
freely configurable 6
Bit 07
freely configurable 7
Bit 08
Operation inhibited
Bit 09
controller inhibit (CINH)
Bit 10
TRIP set
Bit 11
TRIP reset
Bit 12
Freely configurable 12
Bit 13
Freely configurable 13
Bit 14
Freely configurable 14
Bit 15
Freely configurable 15
C0136 CTRLWORD
g
Control word
·
Hexadecimal value is bit−coded.
0
{hex}
FFFF
1
DCTRL_DriveControl
2
CAN1_IN
3
AIF1_IN
C0141 FCODE (setval)
0.00
Freely configurable code (relative analog signals)
·
FCODE_nC141_a
−199.99
{0.01 %}
199.99
C0142 Start options
1
Starting performance of the Servo PLC
·
After power−on
·
After message (t > 0.5 s)
·
After TRIP
0
Start protection
1
Automatic start