C13226 | epl node status mn, C13228 | epl time-out isochronous comm, 11 parameter reference – Lenze E94AYCEP User Manual
Page 90

11
Parameter reference
11.2
Parameters of the communication module for slot MXI1
91
Lenze · E94AYCEP communication module (POWERLINK MN/CN) · Communication Manual · DMS 6.0 EN · 02/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13226
C13228
Parameter | Name:
C13226 | EPL node status MN
Data type: UNSIGNED_8
Index: 11349 = 0x2C55
EPL index: See subcodes
The code indicates the current NMT statuses of the Managing Node.
Each subcode corresponds to an EPL node with node ID = subcode number. The EPL node must be enabled via
Selection list
Info
0 Off
NMT_GS_OFF
25 Initialising
NMT_GS_INITIALISING
41 ResetAppl
NMT_GS_RESET_APPLICATION
57 ResetComm
NMT_GS_RESET_COMMUNICATION
121 ResetConfig
NMT_GS_RESET_CONFIGURATION
28 NotActive
NMT_MS_NOT_ACTIVE
29 PreOp1
NMT_MS_PRE_OPERATIONAL_1
93 PreOp2
NMT_MS_PRE_OPERATIONAL_2
109 ReadyToOp
NMT_MS_READY_TO_OPERATE
253 Operational
NMT_MS_OPERATIONAL
77 Stopped
Only for Controlled Node
30 BasicEthernet
Only for Controlled Node
Subcodes
Info
EPL index
C13226/1
Managing Node
0x1F8E.0xF0
C13226/2
Diagnostics device
0x1F8E.0xFD
C13226/3
router
0x1F8E.0xFE
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13228 | EPL time-out isochronous comm.
Data type: UNSIGNED_32
Index: 11347 = 0x2C53
EPL index: See subcodes
The code defines Controlled Node-specific timeout times to answer the PReq request frames by PRes response
frames. Each subcode corresponds to an EPL node with node ID = subcode number.
Setting range
(min. value | unit | max. value)
0
ns
4294967295
Subcodes
Lenze setting
Info
EPL index
C13228/1
5000 ns
Managing Node
0x1F92.0xF0
C13228/2
5000 ns
Diagnostics device
0x1F92.0xFD
C13228/3
5000 ns
router
0x1F92.0xFE
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT