C14030 | epl device type, C14034 | epl identity object, C14035 | epl device type cn – Lenze E94AYCEP User Manual
Page 105: 11 parameter reference

Lenze · E94AYCEP communication module (POWERLINK MN/CN) · Communication Manual · DMS 6.0 EN · 02/2014 · TD17
106
11
Parameter reference
11.3
Parameters of the communication module for slot MXI2
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C14030
C14034
C14035
Parameter | Name:
C14030 | EPL device type
Data type: UNSIGNED_32
Index: 10545 = 0x2931
EPL index: 0x1000
The code indicates the device type of the EPL node.
Value is bit-coded:
Bit 1 Bit1
Bit 2 Bit2
Bit 3 Bit3
Bit 4 Bit4
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14034 | EPL identity object
Data type: UNSIGNED_32
Index: 10541 = 0x292D
EPL index: See subcodes
The code indicates the Manufacturer's EPL ID no. for Lenze.
Subcodes
Lenze setting
Info
EPL index
C14034/1
59
(0x3B)
Manufacturer's EPL ID no.
0x1018.0x01
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14035 | EPL device type CN
Data type: UNSIGNED_32
Index: 10540 = 0x292C
EPL index: See subcodes
The code contains the device type ID of the declared Controlled Nodes. Each subcode corresponds to a Controlled
Node with the node ID = subcode number.
When being in the configured status, the values must be identical with the device types stored locally in each node
under
.
Subcodes
Lenze setting
Info
EPL index
C14035/1
0
EPL device type CN
0x1F84.0x01
...
...
...
...
C14035/100
0
EPL device type CN
0x1F84.0x64
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT