C14132 | epl cn: link interruptions, C14136 | epl telegram counter, C14203 | epl cn response error – Lenze E94AYCEP User Manual
Page 118: C14205 | epl cn response error: monit. thresholds, C14132, 11 parameter reference

11
Parameter reference
11.3
Parameters of the communication module for slot MXI2
119
Lenze · E94AYCEP communication module (POWERLINK MN/CN) · Communication Manual · DMS 6.0 EN · 02/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C14132
C14136
C14203
C14205
Parameter | Name:
C14132 | EPL CN: Link interruptions
Data type: UNSIGNED_32
Index: 10443 = 0x28CB
EPL index: 0x1C10
The code indicates the counter of the Controlled Node for POWERLINK connection interruptions (
Each event is counted. Every single event is followed by an error message. No threshold value management is
implemented.
Display area
(min. value | unit | max. value)
0
4294967295
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14136 | EPL telegram counter
Data type: UNSIGNED_32
Index: 10439 = 0x28C7
EPL index: 0x1101.0x01
The subcodes of the code indicate a counter for EPL cycles. The counter is started with each mains power-up of the
EPL node at 0. An overflow occurs at 4.294.967.295.
Display area
(min. value | unit | max. value)
0
4294967295
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14203 | EPL CN response error
Data type: UNSIGNED_32
Index: 10372 = 0x2884
EPL index: See subcodes
The subcodes of the code indicate Controlled Node-specific cumulative counters for missing PRes frames. The
behaviour corresponds to a node The behaviour corresponds to subcode 1 of the single error counters.
Each subcode corresponds to an EPL node with node ID = subcode number.
Display area
(min. value | unit | max. value)
0
4294967295
Subcodes
Info
EPL index
C14203/1
Managing Node
0x1C07.0xF0
C14203/2
Diagnostics device
0x1C07.0xFD
C14203/3
router
0x1C07.0xFE
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14205 | EPL CN response error: Monit. thresholds
Data type: UNSIGNED_32
Index: 10370 = 0x2882
EPL index: See subcodes
Setting range
(min. value | unit | max. value)
0
1000
Subcodes
Lenze setting
Info
EPL index
C14205/1
0
Managing Node
0x1C09.0xF0
C14205/2
0
Diagnostics device
0x1C09.0xFD
C14205/3
9
router
0x1C09.0xFE