C13132 | epl cn: link interruptions, C13136 | epl telegram counter, C13203 | epl cn response error – Lenze E94AYCEP User Manual
Page 88: C13205 | epl cn response error: monit. thresholds, C13132, 11 parameter reference

11
Parameter reference
11.2
Parameters of the communication module for slot MXI1
89
Lenze · E94AYCEP communication module (POWERLINK MN/CN) · Communication Manual · DMS 6.0 EN · 02/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13132
C13136
C13203
C13205
Parameter | Name:
C13132 | EPL CN: Link interruptions
Data type: UNSIGNED_32
Index: 11443 = 0x2CB3
EPL index: 0x1C10
The code indicates the counter of the Controlled Node for POWERLINK connection interruptions (
Each event is counted. Every single event is followed by an error message. No threshold value management is
implemented.
Display area
(min. value | unit | max. value)
0
4294967295
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13136 | EPL telegram counter
Data type: UNSIGNED_32
Index: 11439 = 0x2CAF
EPL index: 0x1101.0x01
The subcodes of the code indicate a counter for EPL cycles. The counter is started with each mains power-up of the
EPL node at 0. An overflow occurs at 4.294.967.295.
Display area
(min. value | unit | max. value)
0
4294967295
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13203 | EPL CN response error
Data type: UNSIGNED_32
Index: 11372 = 0x2C6C
EPL index: See subcodes
The subcodes of the code indicate Controlled Node-specific cumulative counters for missing PRes frames. The
behaviour corresponds to a node The behaviour corresponds to subcode 1 of the single error counters.
Each subcode corresponds to an EPL node with node ID = subcode number.
Display area
(min. value | unit | max. value)
0
4294967295
Subcodes
Info
EPL index
C13203/1
Managing Node
0x1C07.0xF0
C13203/2
Diagnostics device
0x1C07.0xFD
C13203/3
router
0x1C07.0xFE
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13205 | EPL CN response error: Monit. thresholds
Data type: UNSIGNED_32
Index: 11370 = 0x2C6A
EPL index: See subcodes
Setting range
(min. value | unit | max. value)
0
1000
Subcodes
Lenze setting
Info
EPL index
C13205/1
0
Managing Node
0x1C09.0xF0
C13205/2
0
Diagnostics device
0x1C09.0xFD
C13205/3
9
router
0x1C09.0xFE
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT