C13103 | epl nmt command: enable, C13104 | epl nmt command: command id, C13105 | epl nmt command: target address – Lenze E94AYCEP User Manual
Page 84: C13110 | epl fault memory, 11 parameter reference

11
Parameter reference
11.2
Parameters of the communication module for slot MXI1
85
Lenze · E94AYCEP communication module (POWERLINK MN/CN) · Communication Manual · DMS 6.0 EN · 02/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13103
C13104
C13105
C13110
Parameter | Name:
C13103 | EPL NMT command: Enable
Data type: UNSIGNED_8
Index: 11472 = 0x2CD0
EPL index: 0x1F9F.0x01
The code enables the NMT command defined via
/
. The values have the following meaning:
• 0: The command is inhibited.
• 1: The command is enabled.
After the NMT command has been executed, the code is automatically set to FALSE.
NMT commands can cause serious faults in the network. Cycle and monitoring errors can occur.
Setting range
(min. value | unit | max. value)
Lenze setting
0
1 0
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13104 | EPL NMT command: Command ID
Data type: UNSIGNED_8
Index: 11471 = 0x2CCF
EPL index: 0x1F9F.0x02
The code defines the command to be executed.
NMT commands can cause serious faults in the network. Cycle and monitoring errors can occur.
Selection list
(Lenze setting printed in bold)
34 StopNode
40 ResetNode
41 ResetCommunication
42 ResetConfiguration
255 No command
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13105 | EPL NMT command: Target address
Data type: UNSIGNED_8
Index: 11470 = 0x2CCE
EPL index: 0x1F9F.0x03
The code defines the destination node of the command via its node address. The node address "255" addresses all
EPL nodes of the network. "0" is an invalid address, a command with destination node "0" is ineffective.
NMT commands can cause serious faults in the network. Cycle and monitoring errors can occur.
Setting range
(min. value | unit | max. value)
Lenze setting
0
255 0
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13110 | EPL fault memory
Data type: INTEGER_8
Index: 11465 = 0x2CC9
EPL index: 0x1001
The code indicates the currently pending errors (according to error classes).
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT