Range

Values

Order designation

E94AYCEP

Communication profile

POWERLINK V2

Communication medium

S/FTP (Screened Foiled Twisted Pair, ISO/IEC 11801 or EN 50173), CAT 5e

Interface for communication

RJ45, Standard Ethernet (according to IEEE 802.3), 100Base-TX (Fast

Ethernet)

Network topology

Tree, star, line

Max. cable length

Number of nodes x 100 m

Cable length between

2 nodes/hubs

max. 100 m

Baud rate

100 Mbps

Type of node

• Managing Node (support of up to 50 nodes)

• Controlled Node

Adjustable by node address (node ID).

Node addresses

(Node IDs)

240 E94AYCEP is Managing Node (max. 50 nodes)

1 ... 100 E94AYCEP is Controlled Node with another E94AYCEP as

Managing Node.

1 ... 239 E94AYCEP is Controlled Node with Managing Node of another

manufacturer.

Voltage supply

External supply via separate power supply unit

+: U = 24 V DC (20.4 V ... 28.8 V), I = 140 mA

- : Reference potential for external voltage supply

Conformities, approvals

• CE

• UL

(see also hardware manual)