4 technical data, 1 general data and operating conditions, Technical data – Lenze E94AYCEP User Manual
Page 15: General data and operating conditions, 4technical data

Lenze · E94AYCEP communication module (POWERLINK MN/CN) · Communication Manual · DMS 6.0 EN · 02/2014 · TD17
16
4
Technical data
4.1
General data and operating conditions
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4
Technical data
4.1
General data and operating conditions
Range
Values
Order designation
E94AYCEP
Communication profile
POWERLINK V2
Communication medium
S/FTP (Screened Foiled Twisted Pair, ISO/IEC 11801 or EN 50173), CAT 5e
Interface for communication
RJ45, Standard Ethernet (according to IEEE 802.3), 100Base-TX (Fast
Ethernet)
Network topology
Tree, star, line
Max. cable length
Number of nodes x 100 m
Cable length between
2 nodes/hubs
max. 100 m
Baud rate
100 Mbps
Type of node
• Managing Node (support of up to 50 nodes)
• Controlled Node
Adjustable by node address (node ID).
Node addresses
(Node IDs)
240 E94AYCEP is Managing Node (max. 50 nodes)
1 ... 100 E94AYCEP is Controlled Node with another E94AYCEP as
Managing Node.
1 ... 239 E94AYCEP is Controlled Node with Managing Node of another
manufacturer.
Voltage supply
External supply via separate power supply unit
+: U = 24 V DC (20.4 V ... 28.8 V), I = 140 mA
- : Reference potential for external voltage supply
Conformities, approvals
• CE
• UL
(see also hardware manual)
Servo Drives 9400 hardware manual
Here you can find the ambient conditions and data on the electromagnetic compatibility