beautypg.com

Phase cabling, Smartpack™ portable, Installing the power supply cable – ETC SmartPack Portable Pack Setup Guide User Manual

Page 4

background image

E T C S e t u p G u i d e

SmartPack™ Portable

SmartPack Portable Setup Guide

Page 4 of 6

Electronic Theatre Controls, Inc.

Installing the Power Supply Cable

Step 1:

Slide the heat shrink tubing, enclosed with the SmartPack, over the power cord so that it

aligns with the back panel strain relief.

Step 2:

Tighten the strain relief until snug. Do not over tighten.

Phase Cabling

Connect power supply cabling for standard installation. To modify factory wiring and change phase
cabling, reference the graphics below:.

W A R N I N G :

Risk of electric shock! Damage or injury may occur if cable is incorrectly fitted.
When working on exposed load circuit wiring the load cables must be unplugged or

the unit disconnected from the power supply.

W A R N I N G :

The power supply cable must be fitted and tested by a competent person.
The supply must be suitable protected by an external over-current device.
The SmartPack must not be exposed to dripping or splashing liquids and no objects

filled with liquid shall be placed on the SmartPack.

SmartLink data to CPU
(Factory wiring)

Strain Relief

Installation wiring

Ea

rth

/ G

rou

nd

L3

L2

L1

N

Earth

N

L1

L2

L3

Single Phase Configuration (Europe)

To Circuit Breakers

(factory wiring)

Important Note

Jumper wires must match specifications for
incoming line wire.

Earth

N

L1

L2

L3

Single Phase Configuration (US)

To Circuit Breakers

2C 1C

2B 1B

2A 1A

Three Phase Configuration

Earth

N

L1

L2

L3

To Circuit Breakers