IES Ethernet PowerModule Operators’ Manual v1.4 Isine
16
4. The screen shows:
IP ADDRESS
[172].22.10.100
5. Use the arrow keys to set the address,
which should be different for each
dimmer module.
6. Press ENT to leave the menu and
record the changes or EXIT (to leave
the previous settings unchanged).
7. Once you have returned to the
ETHERNET SETUP menu, press Ð or
Ï
to choose the NET/UNIVERSE A
menu (there is no need to change the
subnet mask and gateway settings).
Press ENT.
8. The screen shows:
NET A:[0], 01UA
ENTER
9. Use the arrow keys to set the logical
network and universe for DMX-A (in the
screen above network 0 and universe 1
are selected).
10. Press ENT to leave the menu and
record the changes or EXIT (to leave
the previous settings unchanged).
11. Once you have returned to the
ETHERNET SETUP menu, press Ð or
Ï
to choose the NET/UNIVERSE B
menu. Press ENT.
12. The screen shows:
NET B:[0], 02UB
ENTER
13. Use the arrow keys to set the logical
network and universe for DMX-B (in the
screen above network 0 and universe 2
are selected).
14. Press ENT to leave the menu and
record the changes or EXIT (to leave
the previous settings unchanged).
After completing the settings it is advisable to test
the whole system, including any peripherals
connected to the DMX outputs of the networked
dimmers.