4.1

Inspection of boxes

After you have received your order, inspect the boxes carefully for any damage that may have
occurred during shipping. Report any damage to the carrier and to your local Eppendorf
distributor immediately.

4.2

Unpacking

Save the packing materials for possible future use, and be sure to save this Operating Manual
for instruction and reference. User manuals can also be found online, in PDF format, at
www.nbsc.com.

Save the foot shields packed on top of the incubator/shaker, which you will install.

Use a mechanical lifting device to safely lift the incubator/shaker off its shipping pallet and to
transport it to the installation site (see Location on p. 12). You may push the incubator/shaker
a short distance using the built-in castors to roll it. To do this, you may need to rotate the
incubator/shaker feet to raise them so the incubator/shaker will rest on its castors.

Remove the sleeved box sitting on the top shelf inside the incubator/shaker. As indicated in
Delivery package (see Delivery package on p. 7), It contains the two humidity trays, PVC
tubing and several other essential parts.

Remove the foam blocks from the top shelf and save them with the other packing materials.

Locate and remove the parts stored in the humidity trays.

Locate and unpack any other components.

If any part of your order was damaged during shipping, is missing, or fails to operate, please
contact your Eppendorf distributor.

Using your packing list, verify that you have received the correct materials, and that nothing is
missing.

4.3

Utilities requirements

The following utilities requirements are needed for operation:

CAUTION!

Risk of personal injury

A mechanical lifting device is required to safely lift the incubator/shaker.

NOTICE!

Risk of material damage

Never try to lift the incubator/shaker by its door; this would cause permanent damage to the
incubator/shaker.

Never lean on or place objects on the open door.

Utility

Requirement

Electricity

120 V, 50/60 Hz earthed/grounded mains/electrical supply

230 V, 50/60 Hz earthed/grounded mains/electrical supply

CO

2

gas

Cylinder with 100 % CO

2

vapor withdrawal

Hint!

CO

2

gas pressure to device must exceed 7 PSI (0.5 bar) for optimal operation.