beautypg.com

Troubleshooting – Snorkel A38E-sn006001+ User Manual

Page 66

background image

Troubleshooting

Section

5-4

A38E Work Platform

5.1

P

ROBLEM

C

AUSE

A

CTION

All functions inoperable.

Electric motor does not start.

1. Blown main fuse

Check the 300A fuse and replace if necessary

2. Faulty Battery Charger

Connect charger to batteries and check the output voltage. If less than

48v, repair or replace.
Check input voltage to charger. Check the internal charger protection

fuse.

3. Faulty Battery

Charge batteries overnight. Check individual cell voltage. Replace as

necessary.

4. Loose or broken battery leads Check resistance and continuity of each individual lead. Replace as

required.

5. Emergency Stop buttons

contacts failed

Check resistance and continuity of each individual lead. Replace as

required.

7. Loose Upper Control Box

Terminal

Unscrew connector, align locating tabs and reconnect

8. Battery Disconnect plug loose Check and reconnect. Check the internal steel points for pitting or

damage

Electric motor starts but all

functions are inoperable

1. Low hydraulic oil

Check and top up using ISO VG 46 hydraulic oil.

2. Faulty hydraulic pump

Insert a pressure gauge in the G1 port of the valve block. Operate a

function to the limit of stroke. Check that relief valve pressure

develops. Repair or replace.

3. Faulty controller

Check the 10mm cable terminals for tightness.

Electric motor continues to

run when action has ceased

1. Line contactor malfunction

Check the contact faces. Fusing or arcing due to contamination

destroys the contacts. Replace the unit.

Pl.atform elevates very

slowly or not at all

1. Leaking emergency lowering

valves

Check the operating levers and cables.
Check closure of the control knob at the base of the control valve

block.
Remove and replace the cylinder-mounted valves as necessary.

2. Faulty lift valve solenoids

Test the voltage to the mast and jib solenoids. Swap around solenoids

to isolate the problem. Solenoids are not serviceable.

3. Platform overloaded

Remove excessive load.
Check the pressure setting of the hydraulic ‘lift limit’ relief valve (CT11)

on the block. This may only be reset at 215 kg payload in the platform.

l

e

v

e

l

y

r

e

tt

a

B

4. Low

Check the battery cell voltages after recharging. Total battery pack

voltage should exceed 18v.

Charge the batteries or replace faulty battery unit.

Platform drifts down

uncontrollably

1. Leaking emergency lowering /

hose burst valves

Check the operating levers and cables.

Check contamination within the valve.

Check closure of the control knob (CT14) at the base of the control

valve block.

Remove and replace the cylinder-mounted valves as necessary.

2. Cylinder piston seal internal

leakage

Switch off all power functions. Disconnect the hose from the annular

side of the cylinder and check for small oil flow. Oil flow indicates a

faulty cylinder piston seal. Remove and repair the cylinder.

3. Platform is overloaded

Remove excessive weight.

The Safe Working Load is 215

kg for A38

5.1 G

ENERAL

T