Maintenance

Section

4-30

A38E Work Platform

4.22

4.22 CALLIBRATION OF

THE LOAD CELL

If for any reason you have to replace the LOAD CELL

it is important that you complete the following

procedures:

If the LOAD CELL is replaced and /or tampered with
for any reason the loadcell must be re-calibrated

using thefollowing procedure.
Failure to do so could result in serious injury or death.

W A R N I N G

To follow this procedure you need to switch the Ezcal

display in the lower control box into “Calibration mode”.

2.

Scroll to access level. (Enter)

3.

Enter code 2222 for access level 2. (Enter)

4.

Scroll to setups. (Enter)

5.

Scroll to load setups. (Enter)

6.

Scroll to Calibrate load. (Enter)

7.

Redo loaded? Press up arrow for yes, Place

8.

Redo empty? Press up arrow for yes, remove

9.

Use arrow to enter calibration date and press

Enter.

10.

Place 120% of SWL in the platform and verify

the lift function cuts out automatically when

raised off the boom switch.

ESC

ENTER

Esc to leave
Sub-Menu
without saving.

Display

Enter to Save
Entry

Scroll
Left/Right

Change Entry
Up / Down

1.

Switch the machine on and press and hold Esc

for 5 seconds until “Ezlift Menu” is displayed.

SWL in basket and press enter twice.

load from platform and press enter twice.