Maintenance – Snorkel A38E-sn006001+ User Manual
Page 62

Maintenance
Section
4-30
A38E Work Platform
4.22
4.22 CALLIBRATION OF
THE LOAD CELL
If for any reason you have to replace the LOAD CELL
it is important that you complete the following
procedures:
If the LOAD CELL is replaced and /or tampered with
for any reason the loadcell must be re-calibrated
using thefollowing procedure.
Failure to do so could result in serious injury or death.
W A R N I N G
To follow this procedure you need to switch the Ezcal
display in the lower control box into “Calibration mode”.
2.
Scroll to access level. (Enter)
3.
Enter code 2222 for access level 2. (Enter)
4.
Scroll to setups. (Enter)
5.
Scroll to load setups. (Enter)
6.
Scroll to Calibrate load. (Enter)
7.
Redo loaded? Press up arrow for yes, Place
8.
Redo empty? Press up arrow for yes, remove
9.
Use arrow to enter calibration date and press
Enter.
10.
Place 120% of SWL in the platform and verify
the lift function cuts out automatically when
raised off the boom switch.
ESC
ENTER
Esc to leave
Sub-Menu
without saving.
Display
Enter to Save
Entry
Scroll
Left/Right
Change Entry
Up / Down
1.
Switch the machine on and press and hold Esc
for 5 seconds until “Ezlift Menu” is displayed.
SWL in basket and press enter twice.
load from platform and press enter twice.