12. OPTIONS

12 - 4

P/N 0082168

„

GFCI OUTLET

The GFCI (ground fault circuit interrupt) is
located under the platform-control box. To use
the outlet, connect a source of 125 V ac power to
the power plug on the side of the wiring box
inside the right-front of the turntable (or set the
MACHINE/GENERATOR switch to
GENERATOR if an ac generator is installed).

The GFCI protects against short circuits to
ground. When there is a short to ground the
GFCI shuts off power to the electrical outlets.

To reset the outlets:

Unplug the equipment being used.

Press the RESET button on the GFCI.

This should restore power to the outlets. If it
does not, disconnect the source of power (or set
the MACHINE/GENERATOR switch to
MACHINE if equipped with an ac generator) and
refer the problem to a trained service technician.

„

FLASHING LIGHT

The flashing light alerts people that the TB 60 is
present. The light flash at about one flash per
second any time the engine is running. There is
no ON/OFF switch for the flashing light, it cannot
be turned off while the engine is running.

„

SELF-CLOSING GATE

The self-closing gate is designed to automatically
close after you enter or leave the platform. It
helps prevent people from falling off the platform.

„

SPARK ARRESTOR

The spark arrestor prevents incandescent carbon
particles from coming out the tail pipe. The spark
arrestor slows the flow of particles through the
exhaust system. The additional time spent in the
exhaust system lets the carbon completely burn
before it comes out the tail pipe.