8. EMERGENCY OPERATION

8 - 3

P/N 0082168

„

EMERGENCY BLEED-DOWN

Use the emergency bleed-down valve when all
three of the following conditions exist
simultaneously:

the platform needs to be lowered,

the TB 60 engine will not start,

EMERGENCY POWER does not work (dead

batteries or other cause).

D A N G E R

Do not lower the platform or booms onto
electrical wires, people, or other
obstructions.

NOTE: If the main-boom is allowed to drop
below the horizontal, the platform will not
remain level.

1

2

The emergency bleed-down valve (1) is located
under the turntable (2). To use the valve:

1. Very slowly open the bleed-down valve (1) by
turning it counterclockwise. The further it is
opened, the faster the booms come down.

D A N G E R

Be certain you close the emergency bleed-
down valve (1) at the next step. Failure to do
so prevents the main boom from remaining
stationary in an elevated position.

2. Close the emergency bleed-down valve (1)
when the main-boom is horizontal.

8 - 3 (8 - 4 blank)