Troubleshooting – Snorkel TB60 2001 User Manual
Page 65

11. TROUBLESHOOTING
11 - 1
P/N 0082168
All of the actions described in this chapter may
be performed by a TB 60
operator — a trained
and qualified service technician is not required.
Any problem that cannot be fixed by actions
listed below should be referred to a trained and
qualified TB 60
service technician.
The first column, of the following chart, lists
some common problems encountered by TB 60
operators. The second column lists some of the
causes for each problem. The third column lists
remedies.
TB 60 OPERATOR’S TROUBLESHOOTING CHART
PROBLEM
CAUSE
REMEDY
Engine will not start from
the ground-control panel.
1. Switches are set wrong.
(Engine will not crank.)
A. Set BATTERY switch to ON.
At the
ground-control panel:
B. Set MASTER switch to OFF.
C. Set EMERGENCY STOP to UP FOR RUN.
D. Set SELECTOR SWITCH to GROUND.
E. Set MASTER switch to ON for 5
seconds then turn MASTER switch to
START.
2. The MAIN SYSTEM
circuit breaker, on the
wiring box, has tripped.
(Engine will not crank.)
Push the MAIN SYSTEM (25) button
back in. If the button pops out again, refer
the problem to a qualified service
technician.
3. Out of fuel. (Gasoline or
diesel engine cranks but
will not start.)
Add fuel to tank then alternately crank
engine for 20 seconds and let starter motor
cool for 60 seconds (20 on / 60 off).
4. LPG OPTION.
FUEL switch on ground-
control panel is set wrong.
(Engine cranks but will not
start.)
A. Set FUEL switch (ground-control
panel) to L.P.-GAS or GASOLINE.
B. Check the fuel gauge, on top of the
tank, to see if there is fuel in tank.
C. For L.P.-GAS only: Check to see that
fuel valve, on top L.P. tank, is open.
D. Alternately crank engine for 20 seconds
then let starter motor cool for 60 seconds.
Engine will not start from
the platform-control box.
1. Stepping on foot switch.
(Engine will not crank.)
Be sure you are not stepping on the foot
switch, or that the foot switch is not
“blocked” in any way, while you are trying
to start the engine.
2. Switches are set wrong.
(Engine will not crank.)
A. Set the BATTERY switch to ON.
At the
ground-control panel:
B. Set the EMERGENCY STOP switch to
UP FOR RUN.
C. Set the SELECTOR SWITCH to
PLATFORM.
D. Set the MASTER switch to ON.
At the
platform-control box:
E. set the ANTI-RESTART MASTER
SWITCH to OFF.
F. Pull the EMERGENCY STOP switch up.
G. Turn the ANTI-RESTART MASTER
SWITCH to ON.
H. Turn the ANTI-RESTART MASTER
SWITCH to START.
11. TROUBLESHOOTING