Snorkel TB60 2001 User Manual
Page 38
7. OPERATION
7 - 4
P/N 0082168
3. At the ground-control panel, set the
SELECTOR SWITCH (3) to PLATFORM.
4. At the ground-control panel, set the
EMERGENCY STOP switch (4) to UP FOR
RUN.
5. At the ground-control panel, insert the key into
the MASTER switch (5) and turn it to ON (close
the ground-control door).
NOTE: Because you set the SELECTOR
SWITCH to PLATFORM, no “start-up” siren
will sound when you set the MASTER switch
to ON (unless both the EMERGENCY STOP
and ANTI-RESTART MASTER SWITCH, at
the platform-control box, are on).
6. Put on a personnel fall-restraint device.
7. Enter the platform, close the gate, and attach
the lanyard of your fall restraint to one of the
lanyard anchor points (6).
8. At the platform-control box (7) set the
following:
ENGINE SPEED.............. SLOW
DRIVE RANGE ................ LO
BOOM SPEED ................ 3/4 of way to FAST
EMERGENCY STOP ....... up
9. Check the platform-control box circuit breakers
(8) to see that none has popped out.
Y
Starting (from the platform)
Do not attempt to start a TB 60 until the actions
in the previous part of this section (STARTING
FROM THE PLATFORM CONTROL BOX) have
been completed.
1. Turn the ANTI-RESTART MASTER SWITCH
(1) to ON and pause there a few seconds while a
siren sounds to alert others that the TB 60 is
about to start.
NOTE: If you pause 30 seconds or more an
automatic protection feature will prevent the
TB 60 from starting. If that happens, turn the
ANTI-RESTART MASTER SWITCH to OFF
and try again.