S6 Initial blind dialing wait

2

2:255

Seconds

The S6 register determines the number of seconds your modem waits
between the time it takes the telephone off-hook and when it actually
begins dialing. If the modem is not blind dialing, this register is ignored.

S7 Carrier wait

50

1:255

Seconds

The S7 register determines how many seconds the modem waits for a
carrier signal from a remote modem after the dial command line is
executed, or when answering an incoming call. If your modem does not
receive a carrier tone from the remote modem in the specified amount
of time, it hangs up and sends the NO CARRIER message.

S8 Pause time

2

0:255

Seconds

The S8 register determines the delay time for each comma (,)
encountered in the dial command line during the execution of the
D (dial) command.

S9 Carrier detect response time

6

1:255

1/10 second

The S9 register determines how long the carrier must be present before
being recognized by the modem.

S10 Disconnect timing

14

1:255

1/10 second

The S10 register allows you to specify how long an interruption is
necessary before the modem interprets the disruption as a loss of carrier
and hangs up.

If you enter 255, the modem ignores carrier detect status.

S11 Duration and spacing for DTMF dialing

95

50:255

Milliseconds

Register S11 is preset and should remain unchanged to ensure correct
dialing.