beautypg.com

9 troubleshooting – Defi ADVANCE ZD User Manual

Page 26

background image

Warning

If any indication of the problem is found in the product, check to make sure

the product will operate as expected. Failure to do so can lead to serious ac-
cidents.

If any problem is found during using, setting or operating this product, use

the following table to confirm proper operation of the unit. If the operational
problem is not found in the following table, contact the installation personnel
at the store where this product was purchased.

9 Troubleshooting

Condition

Possible Cause

Corrective Action

○ Does not oper-

ate.

○ Power is not

supplied.

○ DC Source

LED of the unit
doesn't light.

○ Wiring of the power supply

wire is improper.

○ The fuse of the power sup-

ply wire is blown out.

○ The locks of the solderless

connectors are not locked
tightly.

○ Check wiring of +B, IGN, GND as per

instructions in this manual.

○ Check wiring and replace the fuse.
○ Check the lock of the solderless con-

nectors.

○ DC Source LED

of the unit is
blinking.

○ There is a wire short

circuit or disconnected wire
somewhere. Maybe there
is something wrong on
gauge.

○ Please reconfirm the wiring and

the gauge according to operation
manual. If any defects are not found,
please ask the shop for inspection.

○ Does not carry

out the ending
mode.

○ The battery wiring is im-

proper.

○ Check wiring of +B as per instruc-

tions in this manual.

○ Check the solderless connector of

battery wiring.

○ Please ask the store for inspection.

○ The illumination

of gauge does
not turn on.

○ The ILM wiring is improper.
○ The locks of the solderless

connectors are not locked
tightly.

○ The brightness level is set at

MANUAL LEVEL:0.

○ The dimmer setting is AUTO

and the outside is bright.

○ Check wiring of ILM as per instruc-

tions in this manual.

○ Check the lock of the solderless con-

nectors.

○ Release illumination cancel function

as per instructions in this manual.

○ Change the dimmer setting.

Condition

Possible Cause

Corrective Action

○ Error (SHORT

or OPEN) is
displayed.

○ There is a wire short circuit

or a wire disconnection
somewhere on sensor or
sensor wire.

○ Check the sensor and sensor wire

as per instructions in this manual. If
any defects are not found, please ask
the shop for inspection.

○ Serial line error

is displayed.

○ Communication error is

occurred between ZD and
ADVANCE Control unit.

○ Check the meter wire as per instruc-

tions in this manual. If any defects
are not found, please ask the shop
for inspection.

○ The RPM is not

displayed cor-
rectly.

○ Wiring of the tachometer

signal is wrong.

○ Setting of the number of

cylinders is wrong.

○ Check wiring as per instructions in

this manual.

○ Check the number of cylinders as

per instructions in this manual.

○ The tachom-

eter is reading
slightly lower
than the original
tachometer.

○ Generally tachometer

readings are about up to 10
%higher than actual RPM.

○ Check if the difference is up to 10%.

This product is designed for high
accuracy and should have little error
margin. If the difference is much
more than 10%, check setting of the
number of cylinders.

○ The speed is

not displayed
correctly.

○ Wiring of the speed signal

wire is wrong.

○ The speed pulse setting is

wrong.

○ Check wiring as per instructions in

this manual.

○ Check the speed pulse as per

instructions in this manual.

○ Cannot set up

the System setup.

○ Several ZDs have the same

display number.

○ Change the display number as per

instructions in this manual.

○ System setup

menu is not
displayed.

○ Active display is not set.

○ Set an active display as per instruc-

tions in this manual.

○ Serial error is

displayed and
the clock re-
turns to 1:00 at
starting engine.

○ The battery is weakening

and power-supply voltage
is lowering.

○ Change the battery.

99

100