Defi ADVANCE ZD User Manual
Page 23
CU OPR
(slide switch position:
M
→
U
)
IF NEITHER OIL PRESSURE NOR FUEL PRESSURE SENSOR IS CONNECTED:
1. Set the slide switch to
M
.
2. The recorded data is replayed by pressing
L
button.
3. Set the slide switch to
U
during playback (or during pause).
4. The peak values are displayed by pressing
M
button.
5. The recorded data is displayed again by pressing
M
button again.
Or set the slide switch to
M
and press
L
button long to
shift to real mode. Playback is not stopped during play peak mode.
IF EITHER OIL PRESSURE OR FUEL PRESSURE SENSOR IS CONNECTED:
1. Set the slide switch to
M
.
2. The recorded data is replayed by pressing
L
button.
3. Set the slide switch to
U
during playback (or during pause).
4. The peak (maximum) values are displayed by pressing
M
button.
5. By pressing
M
button again, The peak values (minimum values of
oil pressure and fuel pressure) are displayed .
5. The recorded data is displayed again by pressing
M
button again.
Or set the slide switch to
M
and press
L
button long to
shift to real mode. Playback is not stopped during play peak mode.
■ Difference between real peak, rec peak, and play peak
Real peak
Rec peak
Play peak
Displayed during
Real mode
Record mode
Playback mode
Displayed values Peak values in all modes Peak value recorded in record mode
Update
In all modes
During record mode
Peak reset
Operatable in real peak
mode
Being reset automatically when
recording is started
8 -7. Warning setup mode
Warning values can be set.
※ Warning function is not applied to either speed or volt.
⇒ Refer to 8 -6-2-1. Warning display
■ Factory default settings of warning values
Gauge
Default
setting
Unit
Setting range
Warning
condition
Warning
output
Minimum Maximum
Turbo/
100
kPa
-100
200
Set value
and above
ON
In-mani press
14.5
PSI
-14.5
29
Tachometer
7000
RPM
300
11000
Set value
and above
ON
Oil press
120
kPa
0
1000
Set value
and below
ON
17.5
PSI
0
145
Fuel press
150
kPa
0
600
Set value
and below
ON
21.8
PSI
0
87
Oil temp
125
℃
0
150
Set value
and above
ON
257
°F
32
302
Water temp
105
℃
0
150
Set value
and above
ON
221
°F
32
302
Exhaust temp
850
℃
0
1100
Set value
and above
ON
1562
°F
32
2010
※ Depending on vehicle type and/or condition, vehicle may be damaged
even if the value is under the factory default setting value of warning (over
the factory default setting value of warning in case of oil pressure and fuel
pressure). Be sure to consult store professional to set warning values.
※ Regarding turbo/in-mani pressure:
ZD cannot display turbo/in-mani pressure, but the warning values can be
set if turbo sensor is installed. The warning buzzer sounds if the setting of
warning buzzer is ON, and warning signal is output if warning output is ON,
but there is no warning display for turbo/in-mani pressure.
93
94