8 -7-1. How to change the warning setting values

CU OPR

(slide switch position:

L

)  

1. Set the slide switch to

L

.

2. Press

L

button to shift to warning setup mode.

3. Select the item to set up by pressing

L

button. The selected item is

highlighted and setting value is displayed. Un-
connected items (sensors) cannot be selected.
The order is as follows:

※ If ADVANCE BF Φ 80 Tachometer are connected, 2 levels of tachometer

warnings can be set.

4. Press

M

button to lower the setting value. Press

R

but-

ton to raise the setting value. Press each button long to change fast.

5. Return the slide switch to

U

or

M

after all the settings are

done.

8 -7-2. Setting of warning output ON/OFF

If ADVANCE Indicator (sold separately) is connected to ZD and the warning
output is on, the ADVANCE Indicator lights up while the item that the output is
on is under condition of warning. While a value exceeds the warning setting,
the zone that the warning item is displayed is highlighted and buzzer sounds
irrespective of the setting of warning output ON/OFF.

CU OPR

(slide switch position:

L

)  

1. Set the slide switch to

L

.

2. Press

L

button to shift to warning setup mode.

3. Select the item to change ON/OFF by pressing

L

button.

ZD OPR

4. Each time

R

SET

button is pressed, the check of IND. OUT □ is

switched over. If the check is on, the warning signal is output while the
item is under the condition of warning.

CU OPR

(slide switch position:

L

)  

5. Return the slide switch to

U

or

M

after all the settings are

done.

8 -8. Error display

When the sensor wiring is disconnected or short-circuit, the item zone is high-
lighted and OPEN or SHORT is displayed. Once OPEN or SHORT is displayed, the
sign keeps being displayed until ignition is turned off. The short-circuit error dis-
plays for oil pressure and fuel pressure are displayed only during short-circuiting.

The error of sensor wiring that is not displayed on
ZD is displayed and highlighted in multi-display
zone (Zone A5). If there are more than 2 errors
that are not displayed, highlights of OPEN or
SHORT are displayed for 2 seconds each in order.

When a communication error between ZD and
ADVANCE Control unit, Serial line error!! is dis-
played.

Turn the ignition off immediately, and then confirm the wiring of the sensor

and the sensor wire. If any defects are not found, please ask the shop for
inspection.