Defi ADVANCE ZD User Manual
Page 14
8
-3. Display setup mode (S2)
Set the rev bar display, indicator lighting, and warning buzzer, etc.
Caution
Set up while the vehicle is stopped.
※ Stop the special display by pressing
L
SELECT
or
R
SET
button once
when you set up if the graphic animation of special display is being played.
ZD OPR
1. By pressing
L
SELECT
and
R
SET
buttons at the same time, the dis-
play shifts to display setup mode, and display setup menu is displayed. REV
BAR SCALE setup is highlighted at the start.
2. Choose the item to change by pressing
R
SET
button. By pressing
L
SELECT
button, the setting is changed.
3. After all the display settings are done, press
L
SELECT
and
R
SET
buttons at the same time to return to real mode.
Setting items
On the screen
Default
REV BAR scale range setting
REV BAR RANGE
3000RPM
REV BAR maximum scale value setting
REV BAR MAX SCALE
8000RPM
Sequential indicator lighting pattern setting
SEQ. IND. PATTERN
SINGLE
Sequential indicator lighting step setting
SEQ. IND. STEP
200RPM
Oil pressure warning limit setting
OIL PRESS WARNING LIMIT 3000RPM
Warning buzzer setting
DISPLAY WARNING BUZZER
ON
Alarm setting
ALARM
OFF
Display number setting
DISPLAY NO.
No.1
8 -3-1. REV BAR scale range setting [REV BAR RANGE]
The scale range of rev bar (the difference between maximum and minimum
scale values) in digital display can be set.
Choose [REV BAR RANGE] by pressing
R
SET
button. Select [3000RPM] or
[4000RPM] by pressing
L
SELECT
button.
8 -3-2. REV BAR maximum scale value setting [REV BAR MAX SCALE]
The maximum scale value in digital display can be set.
Choose [REV BAR MAX SCALE] by pressing
R
SET
button. Each time
L
SELECT
but-
ton is pressed, the value increases by 500RPM.
When the setting of REV BAR RANGE is 3000RPM, the lower limit of REV BAR
MAX SCALE is 3000RPM. When the setting of REV BAR RANGE is 4000RPM, the
lower limit of REV BAR MAX SCALE is 4000RPM.
Setting range:
8 -3-3. Sequential indicator lighting pattern setting [SEQ. IND. PATTERN]
Choose [SEQ. IND. PATTERN] by pressing
R
SET
button. Select [SINGLE]
or [DUAL] by pressing
L
SELECT
button.
⇒ Refer to 8 -9.
Sequential
indicator
8 -3-4. Sequential indicator lighting step setting [SEQ. IND. STEP]
Choose [SEQ. IND. STEP] by pressing
R
SET
button. Select preferred step by
pressing
L
SELECT
button.
Lighting step:
⇒ Refer to 8 -9. Sequential indicator
R E V B A R R A N G E : 3 0 0 0 R P M
REV BAR MAX SCALE: 8000RPM
Display range: 5000RPM to 8000RPM
R E V B A R R A N G E : 4 0 0 0 R P M
REV BAR MAX SCALE: 8000RPM
Display range: 4000RPM to 8000RPM
75
76