beautypg.com

Defi ADVANCE Control Unit (DF07703 Manufactured in and before January, 2012) User Manual

Page 38

background image

Condition

Possible Cause

Corrective Action

○ The RPM is not

displayed correctly.

○ Wiring of the tachometer signal

is wrong.

○ Setting of the number of cylin-

ders is wrong.

○ Check wiring as per instruc-

tions in this manual.

○ Follow tachometer op-

eration manual and wiring

instruction for Speed &

Tachometer signal wire to

confirm the wiring.

○ Check the number of cylin-

ders as per instructions in

this manual.

○ This tachometer

is reading slightly

lower than the

original tachometer.

○ Generally tachometer readings

are about up to 10 % higher

than actual RPM.

○ Check if the difference is

up to 10% . This product is

designed for high accuracy

and should have little error

margin. If the difference

is much more than 10% ,

check setting of the number

of cylinders.

○ Serial line error is

displayed.

○ Communication error is oc-

curred between gauges/ZDs

and the control unit.

○ Check the meter wire as per

instructions in this manual.

If any defects are not found,

please ask the shop for

inspection.

○ Serial line errors are

displayed on all the

connected gauges.

○ More than one pressure

sensors(turbo, oil pressure, and

fuel pressure) short-circuit.

○ In case that the sensor

is broken, it need to be

changed. please ask the

shop for inspection.

76