The peak and warning LEDs in the gauge are lighted up.
4. If the
R
button is pressed, the position changes into 1 → 2 → 3. If
the
M
button is pressed, the position changes into 3 → 2 → 1.
1000rpm, 2000rpm and 3000rpm indicate Position 1, Position2 and posi-
tion3 respectively.
5. Return the slide switch to
U
or
M
.
7 -6. Setup mode (slide switch position :
L
)
By setting warning values, the warning LEDs on the gauges light on when the
gauges reach or exceed the values. In case of oil pressure and fuel pressure,
when the gauge reaches or falls below the value set for warning, the warning
LED lights on. If ZDs are installed, warning setting is displayed on ZD display.
Warning values for gauges and ZDs are set at the same time.
In addition, the illumination color of CR gauges can be selected from 2 colors
in this mode. Illumination color of BF and ZD can not be changed.
■
Warning factory default settings
Setting range
Gauge
default setting Unit Minimum Maximum Lighting condition
Turbo2.0
100
kPa
-100
200
set value and above
Turbo1.2
100
kPa
-100
120
set value and above
In-Mani Press
10
kPa
-100
20
set value and above
Tachometer
7000
rpm
300
9000
set value and above
Oil Press
120
kPa
0
1000
set value and below
Fuel Press
150
kPa
0
600
set value and below
Oil Temp
125
℃
50
150
set value and above
Water Temp
105
℃
20
120
set value and above
Exhaust Temp
850
℃
200
1100
set value and above
Depending on vehicle type and/or condition, vehicle may be damaged
even if the value is under the warning factory default setting value (over the
warning factory default setting value in case of oil pressure and fuel pres-
sure). Be sure to consult store professional to set warning values.
66