Bryant 312AAV User Manual
Page 5
![background image](/manuals/54569/5/background.png)
5. Before removing a new control from it’s container, dis-
charge your body’s charge to the ground. If the control is to
be installed in a furnace, follow items 1 through 4 before
bringing the control or yourself in contact with the furnace.
Put all used and new controls into containers before
touching ungrounded objects.
APPLICATIONS
I. GENERAL
This multipoise furnace is shipped in packaged configuration.
Some assembly and modifications are required when used in any
of the four applications shown in Fig. 4.
II. UPLFLOW APPLICATIONS
In an upflow application, the blower is located below the burner
section, and conditioned air is discharged upward.
III. DOWNFLOW APPLICATIONS
In a downflow application, the blower is located above the burner
section, and conditioned air is discharged downward.
IV. HORIZONTAL LEFT (SUPPLY-AIR DISCHARGE) AP-
PLICATIONS
In a horizontal left application, the blower is located to the right of
the burner section, and conditioned air is discharged to the left.
V. HORIZONTAL RIGHT (SUPPLY-AIR DISCHARGE)
APPLICATIONS
In a horizontal right application, the blower is located to the left of
the burner section, and conditioned air is discharged to the right.
LOCATION
I. GENERAL
This furnace must:
• be installed so the electrical components are protected from
water.
• not be installed directly on any combustible material other than
wood flooring (refer to INTRODUCTION).
• be located as close to the chimney/vent and attached to an air
distribution system. Refer to Air Ducts section.
• be provided ample space for servicing and cleaning. Always
comply with minimum fire protection clearances shown on the
furnace rating plate.
CAUTION: Do not install furnace in a corrosive or
contaminated atmosphere. Make sure all combustion and
circulating air requirements are met, in addition to all
local codes and ordinances.
CAUTION: Do not operate the furnace during construc-
tion. If the furnace is required, use clean outside air free
of chlorine and fluorine compounds for combustion and
ventilation. These compounds form acids that corrode the
heat exchangers and vent system. These compounds are
found in paneling and dry wall adhesives, paints, thin-
ners, masonry cleaning materials, and other solvents.
WARNING: DO NOT install the furnace on its back.
Safety control operation will not perform properly. A
failure to follow this warning can cause a fire, personal
injury, or death.
II. LOCATION RELATIVE TO COOLING EQUIPMENT
The cooling coil must be installed parallel with, or on the
downstream side of the unit to avoid condensation in the heat
exchangers. When installed parallel with the furnace, dampers or
Fig. 4–Multipoise Orientations
A93041
UPFLOW
DOWNFLOW
HORIZONTAL
LEFT
AIRFLOW
AIRFLOW
AIRFLOW
AIRFLOW
HORIZONTAL
RIGHT
Fig. 5–Prohibit Installation on Back
A93043
FRONT
BACK
FRONT
B
A
C
K
—5—