APPENDIX

A-10

If the printer is connected to a parallel port, you can take the following steps;

(1) Open the Maintenance

Information utility, then
select ‘Get the Information’
in the menu.

(2) Select the LPT port you are

using and click the OK
button.

Fig. A-7

(3) Click

the

Exit button.

(4) The dialog box will appear and show the

frequencies of drum unit change, toner
cartridge change and paper jam.

Fig. A-8

Note that each maintenance information is counted under the conditions below;

Information

Conditions

Drum unit change

When drum unit life is 100 pages or more, and the drum counter is
reset. (Maximum counter: 63)

Toner cartridge change

When the toner cartridge is replaced after a Toner Empty error is
stored in NVRAM, then warming-up completes without a Toner
Empty or Toner Low error being detected. (Maximum counter:
127)

Paper jam

When a paper jam occurs. (Maximum counter: 2047)