Settings, Device setting – Konica Minolta Fujitsu Scanner User Manual
Page 188

168
8.1 Scanner Settings
■ Settings
Using the Software Operation Panel, you can configure the following settings for the scanner connected to
the PC.
[Device setting]
Item
Explanation
Selectable parameter
Default
Page counter
(Consumables
counter)
For evaluating the consumable
replacement cycle.
Use this function to reset the counters
after replacing consumables.
Refer to
Replacement Cycle” on page 116
Pad/Pick roller/Separator Roller/Brake
roller
remaining ink level (only for the
imprinter option)
-
Power saving
setting
Select the waiting time before entering
the Power saving mode.
Refer to
Setting range 15 to 55 minutes (set in
steps of 5 min.)
15 min.
Offset setting
Adjust the start position for the docu-
ment scanning.
Refer to
Left right: setting range -2 to 3mm
(set in 0.5mm steps)
Up down: setting range -2 to 3mm (set
in steps of 0.5mm)
left right
0mm
up down
0mm
Scan scale
Adjust the magnification in the feed-
ing direction.
Refer to
Setting range -6.3% to 6.3% (set in
0.1% steps)
0%